Z3 is New Generation 3-part Differential Hematology Analyser designed for small to medium size Laboratory. Large 10.4 inch Colour Display with Touch Screen. High Throughput of 70 Samples/Hour. Less than 52 seconds analysis time of each sample. 21- Parameters with 3-Histogram. Low sample requirement of 10 ul. Only 2 routine Reagents required for sample analysis. Very Low Cost Per Test. Bi-directional LIS Facility for smooth data transfer. Multi level QC options with L-J Graph.
Principle - Impedance for WBC,RBC & Platelet Count. Colorimetry for HGB.
21-Parameters- WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC.
3-Histograms – WBC, RBC, PLT.
Options for GRAN/NEU Results Menu.
Sample Type- Venous Blood, Capillary Blood, Pre-Diluted Blood.
Reagent- Diluent,Lyse, Probe Cleaner (for maintenance)
Sample Volume- 10 ul for Whole Blood Mode, 20 ul for Pre-Diluted Mode.
Z5/ Z50 is New Generation 5-part Differential Hematology Analyser designed to enable all possibilities in small to medium size Laboratory. Tri-angle Laser Scatter with advanced Flow cytometry with Colour Dye enable precise reading of 5-part WBC differentiation even on samples of high Eosinophil. Dedicated Channel and optical method even for Basophil measurement for accuracy on WBC 5-Diff readings than traditional Impedance method. Compact design by placing 2 Lyse inside the instrument and simplified fluid path required very less space inside the laboratory.
Multiple Smart Flags to indicate abnormal Blood Cell and Morphology.
Large 8.4 inch Colour Display with Touch Screen. High Throughput of 60 Samples/Hour. Less than 60
seconds analysis time of each sample. 29- Parameters with 5-Scattergram and 2-Histogram with 4-
Research Parameters. Low sample requirement of 18 ul. Only 3 routine Reagents required for
sample analysis. Very Low Cost Per Test. Bi-directional LIS Facility for smooth data transfer. Multi
level QC options with L-J Graph.
Reagent monitoring and optimized liquid handing software system reduces reagent consumption.
Principle- Flow cytometry and tri-angle Laser Scattering for WBC counting and 5-part Differentiation, Impedance method for RBC & Platelet Count.
Colorimetry Cyanide free reagent for HGB.
Parameters- 25 reportable Parameters- WBC,LYM#,MONO#,NEU#, BAS#, EOS#, LYM%, MONO%, NEU%, BAS%, EOS%, RBC, HGB, HCT, MCV,MCH,MCHC,RDW-CV,RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC.
4-Research Parameters- ALY%, ALY#, LIC%, LIC#.
3-D DIFF Scatter gram
2-D BASO Scatter gram
2-Histograms – RBC and PLT.
Sample Type-Venous Blood, Capillary Blood, Pre-Diluted Blood.
Reagent-Diluent, LD Lyse, LB Lyse Probe Cleaner (for maintenance)
Sample Volume- 18 ul for Whole Blood Mode.
QC Rule- L-J Graph, X-B, X-M, X-R.
Storage- More than 50,000 results including numeric and graphical information.
EXZ 6000 is New Generation Automated 5-part Differential Hematology Analyser with Auto Loader for continuous loading of 50 samples at a time. Sample info can be entered by Bar code management. Sample automatic mixed before taking reading. Result of sample can be viewed in single page with all parameters, flagging and graph. Tri-angle Laser Scatter with advanced Flow cytometry with Colour Dye enable precise reading of 5-part WBC differentiation even on samples of high Eosinophil. Dedicated Channel and optical method even for Basophil measurement for accuracy on WBC 5-Diff readings than traditional Impedance method.
Multiple Smart Flags to indicate abnormal Blood Cell and Morphology.
Large 12.1 inch HD Colour Display with Touch Screen. High Throughput of 90 Samples/Hour in CBC
mode and 70 Samples/Hour in CBC+DIFF mode. 4 types of Sampling Mode for various options of
Whole Blood and Capillary sampling. 38- Parameters with 5-Scattergram and 2-Histogram with 13-
Research Parameters. Low sample requirement of 45 ul for Auto loader Whole Blood mode. Only 4
routine Reagents required for sample analysis. Very Low Cost Per Test. Bi-directional LIS Facility for
smooth data transfer. Multi-level QC options with L-J Graph.
Reagent monitoring and optimized liquid handing software system reduces reagent consumption.
Principle- Flow cytometry and tri-angle Laser Scattering for WBC counting and 5-part Differentiation, Impedance method for RBC & Platelet Count. Colorimetry Cyanide free reagent for HGB.
Parameters- 25 reportable Parameters- WBC, LYM#, MONO#, NEU#, BAS#, EOS#, LYM%, MONO%, NEU%, BAS%, EOS%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-CV,RDW-
SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC.
13- Research Parameters- ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#, LP%, LP#, PC%, PC#, LMR%, LMR#, NLR%, NLR#, PLR%, PLR#.
3-D DIFF Scatter gram
3 2-D DIFF Scatter gram
3 Histograms
Sample Type- Venous Blood, Capillary Blood, Pre-Diluted Blood.
Reagent- Diluent ,LD1 Lyse, LD2 Lyse, LB Lyse Probe Cleaner (for maintenance)
Sample Volume- 18 ul for Whole Blood Mode.
QC Rule- L-J Graph, X-B,X-M,X-R.
Storage- More than 100,000 results including numeric and graphical information
Advanced Coagulation Analyser required less volume of reagent and sample, provides fast and accurate results of Coagulation Assays like Prothrombin Time (PT), ApTT, TT, FIBRINOGEN. Instrument designed and developed by Erma Inc, Tokyo, Japan ensures better accuracy and durability. Turbo-Densitometric principle uses both Mechanical and Optical method to detect micro fibrin in the sample during reaction. Built-in Incubator with Timer and Printer. Auto sensing of Cuvette insertion and reagent dispensing. Storage data of 1000 sample results.
Principle: Turbo-Densitometric
Method: Opto-Mechanical
Test Channel: One
Performing Test: PT, APTT, TT, FIBRINOGEN
Reagent Incubation Position: 2
Sample Incubation Position: 4
Temperature Control: 37 degree C.
Storage: 1000 results.
Display: Backlit LCD
Keypad: Soft touch Membrane.
Printer: Thermal